MICROPROCESSOR-BASED
TEMPERATURE/ RELATIVE
HUMIDITY RECORDER
|
CT485B
- Includes 120
Double Sided
Charts
Available in Computer Room White or Charcoal Gray
Versatile Remote Mounting Sensor
Convenient Front Panel Programming
200 mm (8") Chart for 1, 7, or 32-Day Recording
Fully Electronic Microprocessor Control
Benchtop or Wall Mounted
Alarm Contact Standard
Sensors Not Recommended for Use in a Corrosive Environment
The new Model CT485B completely self-contained temperature/
relative humidity recorder is microprocessor based to accurately
measure, indicate and record temperature and relative humidity.
|
This rugged unit comes
standard with alarms. They contain a single, integral relay contact which
closes in response to an alarm condition. Simultaneous high and low alarm
points for temperature and relative humidity are user selectable. When
the current conditions exceed any of the preset values, the 2 Amp relay
contact closes and an audible alarm sounds. Flipping open a hinged front
panel door permits access to the power switch and controlling functions
of the recorder. The door comes with a locking mechanism. The user may
select 1, 7 or 32 day operation, program the instrument to record in ºC
or ºF, and access alarm and calibration controls or max/min functions.
A separate 3-position switch next to the digital display selects a ºC,ºF
or %RH readout. The chart drive is stepper controlled for precision, and
a unique magnetic retaining knob eliminates the possibility of paper tear.
Calibration of alarm models is digital, and a user may make calibration
adjustments in the field using the convenient panel pushbuttons. An optional
calibration lockout cover prevents unauthorized changing of calibration
codes. A stabilizing arm provides added stability for benchtop use. The
arm conveniently rotates under the unit for wall mounting. Recessed rear
mounting slots and a wall template enable easy wall mounting. A decorative
cover for the stabilizing arm is supplied for wall mount use.
A standard 110 Vac power adaptor is supplied for continuous long-term
operation, along with four D-cell batteries for backup power or field
use. Each unit includes 6 feet of cable for remotely mounting the sensor.
A sensor holder clip is provided. Units come standard with two chart light
bulbs. When using the ac power adaptor, these bulbs provide easy viewing
of the chart in dimly lit conditions. A switch is provided to allow the
chart lights to be turned on or off.
SPECIFICATIONS
Measurement
Inputs: Temperature and humidity, with plug-in external sensor, removable
for remote location, 6' extension cable included; 0.02 to 1.20 Vdc signal
with voltage input adaptor
TEMPERATURE
Range: -17 to 49ºC (2 to 120ºF)
Accuracy: ▒1ºC
Sensor: Solid state
Response Time: 5 minutes for 63% step change
Display Resolution: 1ºC/1ºF
HUMIDITY
Range: 2 to 98% RH
Accuracy: ▒3% @25ºC, between 20 and 90% of range (▒5% below
20% and above 90% @25░C)
Sensor: resistive polymer. Not recommended for use in corrosive
air environments
Response Time: 5 minutes for a 30 to 80% step change
Display Resolution: 1% RH 2 1/2 digit LCD, 0.5" high; low battery
Display Modes: Front panel switchable between ºC, ºF
and %RH for continuous digital display; max/min storage for both temperature
and humidity or flashing to indicate alarm condition
ELECTRONICS
Type: Microprocessor-controlled and linearized high and low peak
hold for both temperature and humidity, re-initializes position at every
chart change
CHART
Type: 8" circular, linear radial divisions; 1, 7 and 32 days, ºC
and ºF scales
CHART DRIVE
Type: Stepper motor
Ranges: 1, 7 and 32 day, selectable
Accuracy: 1% of rotation
Chart Hold Down: magnetic hub lock
RECORDING PENS
Type: Disposable fiber tip, red for temperature, blue for humidity
PEN DRIVES
Type: Motorized linear screw drive
Deadband: 1ºF, 1% RH
Zero: Automatic zero during chart change or power interruption
Penlift: Automatic on door opening; pens are door mounted and swing
clear of the chart when door opens
Pen Arms: Clear plastic to allow full chart viewing
OPERATING CONDITIONS (Recorder)
Temperature: 0 to 49ºC (32 to 120ºF)
Humidity: 0 to 90% RH, non-condensing
OPERATING CONDITIONS (Sensor Remote)
(Sensors not recommended for use in a corrosive environment)
Temperature: -17 to 49ºC (2 to 120ºF)
Humidity: 0 to 98% RH
ALARMS
Alarms: User-selectable for high or low temperature and humidity
Audible Alarm: Integral piezoelectric beeper
Alarm Relay Contacts: 1 Amp, 30 Vdc Normally open, single pole,
single throw (SPST)
Power (Recorder): Four D cells or 9Vdc/110, 50/60 Hz power adaptor
(supplied); 220 Vac power adaptor supplied where applicable
Battery Life: more than 1 month continuous operation in 32-day
mode (average conditions)
Power Requirements: 300 mA "normal" during pen movement
for battery (dc) power; 500 mA "normal" during pen movement
for ac power using ac adaptor with chart lights on (Note: the light
bulbs drain 200 mA of current)
DC Power Jack Voltage: 8.3 to 12.4 Vdc (nominal 9 Vdc), 1 Amp max.
MECHANICAL
Dimensions: 33.5 H x 27.1 W x 6.7 cm D (13 3/16" x 10 11/16" x
2 5/8")
Weight: Approx. 3 Kg (7 lbs) including batteries
Mounting: "Keyhole" slots for wall mounting; foot cover
for benchtop use
Case: Rugged ABS plastic
ANALOG VOLTAGE INPUT ADAPTOR
Input: 20 mVdc to 1200 mVdc records as 2 to 120ºF, input protection
up to 20 Vdc or 10 Vac RMS
Input Impedance: 330 Kohms min.
Input Connections: Banana jacks, 19 mm (0.75") spacing
Cable Length:
305 mm (12")
|